Home

Career for electrical and electronics engineers


Electrical and electronics engineering has a great scope in the world. As we know without electricity we can even imagine our life. Each and every steps of our life electricity play the important role.Some of the best job that the electrical and electronics engineers are:
  • Aerospace Engineers
  • Electronics Engineers
  • Engineering Manager
  • Marine Architect
  • Mathematician
  • Mechanical Engineer
  • Mining and Geological Engineer
  • Naval Architect-er

The useful skills that the electrical and electronics engineers :

  • Accept the responsibility and face it and done it 
  • Communicate orally 
  • Identify, analyze, and solve the problems 
  • Work without supervision 
  • Interest in computing/technical design
  • Practicality and creativity of electical system
  • Work as a team member with coordination
  •  Careful work and accuracy
  • Diagnostic ability in field 
  • Analytical skills of project
  • Communication skills 
  • Interest in electromagnetism equipment
  • Interest in electronics, machines,
  • Investigating, identifying skills
  • Logical thinking
  • Problem solving skills
  • Work independently and in teams

Scope of electrical and electronics engineers


Scope

Electrical and Electronics engineers conduct mainly on research and
design, develop, test of the development of
electronic systems and the manufacture of electrical and
electronic equipment and devices. They are responsible for a
wide range of technologies. They design, develop, test,
and supervise the manufacture of electrical and electronic
equipment. Some of this equipment includes broadcast and communications systems; electric
motors, machinery controls, lighting, and wiring in buildings, automobiles, aircraft, and radar
and navigation systems; and power generating, controlling, and transmission devices used by
electric utilities. Many electrical and electronics engineers also work in areas closely related to
computers.

Preparation  

If your goal is to achieve a fulfilling career, building the groundwork will take some care. While
in school, keep your options as wide as possible -- the further you go, the narrower your focus
must become. While the decision to major and minor is an important step, your decision should
not be limited to an engineering curriculum or even to the classroom.

strip-chart recorder

Strip-chart Recorder


Strip-chart recorder is the graphic recorder which display and store a pen and ink record of the history of some physical event which records one or more variables with respect to time.Its is an X-t recorder.
It can perform the measurement as follows steps:
  1. A long roll of graph paper moving vertically.
  2. A system for driving the paper at some selected speed. A speed selector switch is generally provided chart speed of 1-100 mm/s are usually used.
  3. A stylus for making marks on the moving graph paper. the stylus moves horizontally in proportional to the quantity being recorded.
  4. A stylus driving system which moves the stylus in a nearly exact replica or analog of the quantity being recorded
A range selector s/w is used so that i/p to the recorder drive system is within the acceptable level.

X-Y Recorder

Best device t0 plot Relati0n of tw0 vAriaBle 


X-Y recorder is the best device to plot relation of two variable.It is an  instrument which gives a graphic record of the relationship between two variables. In strip chart recorder, self balancing potentiometer is used and these self balancing potentiometer is used and these self balancing potentiameter plot the emf as a function of time. In X-Y recorder, an emf is plotted as a function of another emf. This is done by having one self balancing potentiometer control the position of the roll while another self balancing potentiometer controls the position of recording pens. 

The marking mechanism in X-Y plotter may be
  1.     Marking with ink filled stylus 
  2.     Marking with heated stylus 
  3.     Chopper bar 
  4.     Electric stylus 
  5.     Optical marking method
A signal enters each of the two channels. The signals are attenuated to the inherent full scale range of the recorder. The signal then passes to a balance circuit where it is compared with an internal reference voltage. The error signal (i.e the difference between the input signal voltage and the reference voltage ) is fed to a chopper which converts dc signal to an ac signal. The signal is then amplified in order to actuate a servo meter which is used to balance the system and hold it in balance as the value of quantity being recorded changes.
The action described above takes place in both axes simultaneously. And hence, we get record of two variable in same graph.

Factors affecting Corona

                               Factors Affecting Corona 


The phenomenon of corona is affected by the physical state of the atmosphere as well as by the conditions  of the line. The corona depends on the following factors:

  1. Atmosphere:  As corona is formed due to ionization of air surrounding the conductors,therefore, it is affected by the physical state of atmosphere. In the stormy weather, the number of ions is more than normal and as such corona occurs at much less voltage as compared with fair weather.
  2. Conductor size.  The corona effect depends upon the shape and conditions of the conductors. The rough and irregular surface will give rise to more corona because unevenness of the surface decrease the value of breakdown voltage. Thus a stranded conductor has irregular surface and hence gives rise to more corona that a solid conductor.  
  3. Spacing between conductors. If the spacing between the conductors is made very large as compared to their diameters, there may not be any corona effect. It is because larger distance between conductors reduces the electrostatic stresses at the conductor surface, thus avoiding corona formation.
  4. Line voltage. The line voltage greatly affects corona. If it is low, there is no change in the condition of air surrounding the conductors and hence no corona is formed. However, if the line voltage has such a value that electrostatic stresses developed at the conductor surface make the air around the conductor conducting, then corona is formed.

Report on solar power water pumping




           Report on solar power water pumping

                                                           
 The system consists of a photo-voltaic (PV) array, a permanent magnet (PM) DC motor and a helical rotor pump. The operation of the PV array is analyzed using PSPICE. The efficiency of the system is improved with a maximum power point tracker (MPPT) and a sun-tracker. Simulation and field test results are presented.
The main advantage is that the sunlight is intense, when the demand for irrigation is high. In addition to the solar energy available at the time of use so that the independent farmers or fuel supply of electrical cables. Solar pumps have the potential to revolutionize small-scale irrigation in developing countries in the near future. The technical feasibility of solar energy (photo-voltaic) established. The pumps were important limiting factor is the high cost and lack of familiarity with the technology they require a concerted effort in the training of technicians and large-scale introduction in a region with already adequate technical assistance . However, incentives and initiatives, the payments to be made by multinational companies / authorities of the scheme in rural areas for small-scale irrigation systems in remote rural areas where electrification is an expensive affair spread.  The system model is the introduction of solar water pumps and irrigation systems to help provide sustainable development for farmers in the United Nations or in rural areas electrified. Various agencies and financial institutions are to assist in the development of credit-control to target rural area without electricity.
In conclusion, photo-voltaic power for irrigation is cost competitive with traditional energy sources for small ,remote applications, if the total system design and utilization timing is carefully considered and organized to use the solar energy as efficiently as possible. In future, when the prices of fossil fuels rise and the economic advantages of mass production reduce the peak watt cost of the photo-voltaic cell, Pumping Water for Irrigation Using Solar Energy.

Electromagnetic current-meter


   Electromagnetic (e/m) current-meter is an electrical induction-measurement instrument, with no moving parts, mounted in a totally enclosed streamlined probe. The probe can be mounted on rods and held at various depths or suspended on a cable.

The e/m meter has the advantages of being smaller and having a wider measurement range than the propeller meters. It is particularly useful at very low velocities when propeller meters become erratic. Its sensitivity and lower vulnerability to fouling from weeds and debris make it attractive for use in heavily polluted or weedy streams.Each unit is provided with a surface control box with a digital display and dry-cell batteries. A set of stainless steel wading rods is also standard equipment. Latest models have built-in battery-charger circuits.It will be appreciated that since each river is unique, a careful assessment of its width, depth, likely flood velocities, cable-support facilities, availability of bridges, boats, etc. needs to be made before a discharge measurement programme can begin.The discharge at the chosen measuring point is best obtained by plotting each velocity observation on a cross section of the gauging site with an exaggerated vertical scale. Isovels (velocity profiles – contours of equal velocity) are then drawn and the included areas measured by a planimeter. Alternatively, the river may be subdivided vertically into sections and the mean velocity of each section applied to its area. In this method the cross-sectional area of any one section, where measurements, are taken should not exceed 10 per cent of the total cross-sectional area.

Power line communication

Power line communication (PLC) presents an interesting and economical solution for Automatic Meter Reading (AMR). If an AMR system via PLC is set in a power delivery system, a detection system for illegal electricity usage may be easily added in the existing PLC network. In the detection system, the second digitally energy meter chip is used and the value of energy is stored. The recorded energy is compared with the value at the main kilo Watt-hour meter. In the case of the difference between two recorded energy data, an error signal is generated and transmitted via PLC network. The detector and control system is proposed. The architecture of the system and their critical components are given. The measurement results are given.

The Pico-hydro power


                                     tHe PiCo HyDrO PoWeR


The Pico hydro is hydro power with a maximum electricaloutput of five kilowatts (5kW). Hydro power systems ofthis size benefit in terms of cost and simplicity from differentapproaches in the design, planning and installation than thosewhich are applied to larger hydro power. Recent innovationsin pico-hydro technology have made it an economic source ofpower even in some of the world’s poorest and mostinaccessible places. It is also a versatile power source. ACelectricity can be produced enabling standard electricalappliances to be used. Common examples of devices whichcan be powered by pico-hydro are light bulbs, radio andtelevision.

Wireless power transfer objective


Wireless Power transfer objective:

The objective of this paper is to give an idea of  wireless power transfer objective which is in developing stage and it can be a future existence. Due to the extinguishing energy resources, there is a serious search of alternative energy resources which are endless and Eco-friendly. The answer for this is wireless power transfer which came in 17th century . It consists of microwaves for transmission of electromagnetic radiation, and for vibrating the objects resonance concept is used and solar cells for sun’s radiation in outer space. Research has been going in various countries to bring W P T into a practical environment.